ROOF CONSTRUCTION & INSULATION |
Roof Construction | 180*58*1.5 U framed, 45mm of EPS insulated sandwind panel (rain waters are taken out by inside of corner post. | ||
|---|---|---|---|---|
| DOOR JOINERIES | External door (1, 2 mm galvanized metal sheet frame) | 935/1981 mm Insulated steel sheet doors (outer size). 0.5 mm film covered COIL COATING system RAL9002 painted Galvanized Sheets, both sides are EPS filled, wing wide 45 mm |
||
| Internal door (1, 2 mm galvanized metal sheet frame) | 840/1960 mm Mdf-lam Pressed door (outer dimensions) | |||
| Door for Wet areas (1, 2 mm galvanized metal sheet frame) | 620×1960 mm Mdf-lam Pressed door (outer dimensions) | |||
| Door Lock and Handle | External door locks are cylindirical, internal doors have encased locks. Brandmark ITO or KALE, yellow or grey coloured metal door handles. | |||
| WINDOW JOINERIES (FLY SCREEN ARE INCLUDED) | Window 1.2 mm galvanized metal sheet) | 970/1200 mm PVC Framed Windows | ||
| Kitchen WC Shower | 120 mm circled electrical aspirator | |||
| Double Glass (Glazing) | 4+9+4 mm – Brand: SISECAM | |||
| PAINT | External door and window frames | Prepainted with COIL COATING SYSTEM | ||
| Internal Door Frames | Prepainted with COIL COATING SYSTEM | |||
| Outer Corner | 1 layer rapid primer + 1 layer semi-synthetic oilt paint | |||
| Other metal parts (base plate(chassis), bearing construction) | 1 layer rapid Primer | |||
| SANITARY INSTALLATION ON PLASTER | Lavatory /w ashbasin | 37×45 cm Wall Type | ||
| Lavatory and shower taps | Taps are wall mounted in cold water installation lavatories and taps have outlets from lavatories in hot water installation lavatories | |||
| Water Closet | Western Style Water Closet, Plastic Flushing cistern WC taps |
|||
| Shower Tray | 80×80 cm Acyrilic | |||
| Kitchen Sink | Chromium-plated 50/100 cm double, lower chipboard cupboard. Top cupboard above the cupboard is not included. | |||
| Accessories | PVC paper holder, soap dish, mirror, shelf, closet cover | |||
| specifications | Location | AUSTRALIA |
|---|---|---|
| Company | ||
| Product | PortaTech DEMOUNTABLE PORTABLE OFFICE | |
| production type | Modular Construction with special formed and furnace painted galvanized metal sheet body. TYPE: Rated Dimension: 2.40×6.00×2.60 m. Outer Clear Size: 2.460×5.930×2.60 m. All materials certificated by TSE. |
|
| technical datas | Snow Load | 80 kg/m² |
| Wind Speed | 102 km/saat | |
| External Wall Heat Transmission Coefficient | K: 0.26 Kcal/m²hC | |
| Internal Wall Heat Transmission Coefficient | K: 0.26 Kcal/m²hC | |
| Roof Heat Transmission Coefficient | K: 0.68 Kcal/m²hC | |
| Floor Heat Transmission Coefficient | K: 3.85 Kcal/m²hC | |
| Base-Plate (chassis) Load Capacity | 200 kg/m² Calculated in accordance with T.S 498 | |
| external walls | External Wall Height | 2600 mm |
| Internal Clear Height | 2320 mm | |
| Outer Surface Covering | 50 mm thickness of PortaTech Thermal Performance Panels Outer Surface Covering: 0.45 mm thick of RAL 9002 coil painted galvanized sheets Insulation in between: 45 mm thickness of Polistren foam (16 kg/m3) Inner Surface Covering: 0.45 mm thick of RAL 9002 coil painted galvanized sheets |
|
| internal walls | Internal Wall Height | 2320 mm |
| Internal Wall Panel | 50 mm thickness of PortaTech Thermal Performace Panels Fibercement Insulation in between: 45 mm thickness of Polistren foam (16kg/m3) Inner surface covering: 0.45 mm thick of RAL 9002 coil painted galvanized sheets |
|
| floor covering | Construction | 100*58/50 U/C 1.50 / 2.0 mm Galvanized DX51+Z C/U sectioned cold formed profiles |
| Covering | PVC Roll as floor covering on the 16mm thick FIBER Cement board-Hekimboard brandmarked (non-combustible) DIN 4102-2A1 Class | |
| ceiling covering | Covering | 0.45 mm thickness of RAL 9002 painted galvanized sheets |
| Electrical | Complies with Australian Standards |
|---|---|
| lifting system | The loading and unloading facility shall be made by connecting the steel ropes lying in the same interval to the iron. Lifting eyes mounted hiddenly on the corners, to the lockers. If required the containers shall be two or multi-storied. The transport system of all containers will be organized by concerning that specification. WC, Shower containers will be produced with insulation or without any insulation. |